• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Journal of Soil Sciences and Agricultural Engineering
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 16 (2025)
Volume Volume 15 (2024)
Volume Volume 14 (2023)
Volume Volume 13 (2022)
Volume Volume 12 (2021)
Volume Volume 11 (2020)
Volume Volume 10 (2019)
Volume Volume 9 (2018)
Volume Volume 8 (2017)
Volume Volume 7 (2016)
Volume Volume 6 (2015)
Volume Volume 5 (2014)
Volume Volume 4 (2013)
Volume Volume 3 (2012)
Volume Volume 2 (2011)
Issue Issue 12
Issue Issue 11
Issue Issue 10
Issue Issue 9
Issue Issue 8
Issue Issue 7
Issue Issue 6
Issue Issue 5
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 1 (2010)
Volume Volume 34 (2009)
Volume Volume 33 (2008)
Volume Volume 32 (2007)
Volume Volume 31 (2006)
Volume Volume 30 (2005)
Volume Volume 29 (2004)
Volume Volume 28 (2003)
Volume Volume 27 (2002)
Volume Volume 26 (2001)
Volume Volume 25 (2000)
Almuhanna, E. (2011). EFFECT OF NATURAL AND MECHANICAL VENTILATION SYSTEMS ON AIR CONTAMINANTS OF POULTRY HOUSING IN AL-AHSA (ESTERN PROVINCE), SAUDI ARABIA. Journal of Soil Sciences and Agricultural Engineering, 2(3), 295-314. doi: 10.21608/jssae.2011.55443
E. A. Almuhanna. "EFFECT OF NATURAL AND MECHANICAL VENTILATION SYSTEMS ON AIR CONTAMINANTS OF POULTRY HOUSING IN AL-AHSA (ESTERN PROVINCE), SAUDI ARABIA". Journal of Soil Sciences and Agricultural Engineering, 2, 3, 2011, 295-314. doi: 10.21608/jssae.2011.55443
Almuhanna, E. (2011). 'EFFECT OF NATURAL AND MECHANICAL VENTILATION SYSTEMS ON AIR CONTAMINANTS OF POULTRY HOUSING IN AL-AHSA (ESTERN PROVINCE), SAUDI ARABIA', Journal of Soil Sciences and Agricultural Engineering, 2(3), pp. 295-314. doi: 10.21608/jssae.2011.55443
Almuhanna, E. EFFECT OF NATURAL AND MECHANICAL VENTILATION SYSTEMS ON AIR CONTAMINANTS OF POULTRY HOUSING IN AL-AHSA (ESTERN PROVINCE), SAUDI ARABIA. Journal of Soil Sciences and Agricultural Engineering, 2011; 2(3): 295-314. doi: 10.21608/jssae.2011.55443

EFFECT OF NATURAL AND MECHANICAL VENTILATION SYSTEMS ON AIR CONTAMINANTS OF POULTRY HOUSING IN AL-AHSA (ESTERN PROVINCE), SAUDI ARABIA

Article 3, Volume 2, Issue 3, March 2011, Page 295-314  XML PDF (831.06 K)
Document Type: Original Article
DOI: 10.21608/jssae.2011.55443
View on SCiNiTO View on SCiNiTO
Author
E. A. Almuhanna
Dept. Agric. Systems Engineering, King Faisal University, Saudi Arabia
Abstract
 A field study was conducted to assess the effect of natural and mechanical ventilation systems on air contaminants of poultry housing under eastern province of Saudi Arabia climatic conditions. The concentration and particles size distribution of airborne particles and gases were measured and analyzed inside two different poultry housing. The obtained data showed that, the mean total suspended particles concentration (TSP) inside the poultry housing that used natural ventilation system (N.V.) was 12.47 mg/m3, the particulate matter with a diameter less than or equal to 10 µm (PM10) concentration was 4.81 mg/m3, and the particulate matter with a diameter less than or equal to 2.5 µm (PM2.5) concentration was 0.18 mg/m3. Whereas, in the poultry housing used mechanical ventilation system (M.V.), these concentrations, respectively, were 4.61, 2.26, and 0.09 mg/m3. The TSP values were greater than the suggested threshold values for indoor air contaminants in livestock building, however, the PM2.5 values of both housing did not exceed the suggested threshold values for indoor air contaminants in livestock building. The geometric mean diameter (GMD) based on the mass concentration of particles in the natural and mechanical ventilation systems was 8.63 and 8.38 μm, respectively. The concentration of ammonia (NH3), carbon dioxide (CO2), sulfur dioxide (SO2), oxides of nitrogen (NO2), and hydrogen sulfide (H2S) was also measured inside the poultry housing. The obtained results also revealed that, the ammonia was the dominant gas in both housing. Moreover, the majority of gases did not exceed the threshold values. Using the mechanical ventilation system, the concentration of airborne particles and toxic gases inside the poultry house was strongly affected by the barn ventilation rate.
Keywords
Air Quality; Dust; ammonia; Gases; Airborne particles
Statistics
Article View: 226
PDF Download: 538
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.