• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Journal of Soil Sciences and Agricultural Engineering
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 16 (2025)
Volume Volume 15 (2024)
Volume Volume 14 (2023)
Volume Volume 13 (2022)
Volume Volume 12 (2021)
Volume Volume 11 (2020)
Volume Volume 10 (2019)
Volume Volume 9 (2018)
Volume Volume 8 (2017)
Volume Volume 7 (2016)
Volume Volume 6 (2015)
Volume Volume 5 (2014)
Volume Volume 4 (2013)
Volume Volume 3 (2012)
Volume Volume 2 (2011)
Volume Volume 1 (2010)
Issue Issue 12
Issue Issue 11
Issue Issue 10
Issue Issue 9
Issue Issue 8
Issue Issue 7
Issue Issue 6
Issue Issue 5
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 34 (2009)
Volume Volume 33 (2008)
Volume Volume 32 (2007)
Volume Volume 31 (2006)
Volume Volume 30 (2005)
Volume Volume 29 (2004)
Volume Volume 28 (2003)
Volume Volume 27 (2002)
Volume Volume 26 (2001)
Volume Volume 25 (2000)
Abdellatif, S., Ibrahim, M., Ellithy, M. (2010). A COMPARTIVE STUDY ON TWO DIFFERENT EVAPORATIVE COOLING SYSTEMS FOR PRODUCTING CUCUMBER CROP UNDER HOT-HUMID SUMMER CONDITIONS. Journal of Soil Sciences and Agricultural Engineering, 1(10), 1015-1036. doi: 10.21608/jssae.2010.75499
S. M. Abdellatif; M. M. M. Ibrahim; M. M. H. Ellithy. "A COMPARTIVE STUDY ON TWO DIFFERENT EVAPORATIVE COOLING SYSTEMS FOR PRODUCTING CUCUMBER CROP UNDER HOT-HUMID SUMMER CONDITIONS". Journal of Soil Sciences and Agricultural Engineering, 1, 10, 2010, 1015-1036. doi: 10.21608/jssae.2010.75499
Abdellatif, S., Ibrahim, M., Ellithy, M. (2010). 'A COMPARTIVE STUDY ON TWO DIFFERENT EVAPORATIVE COOLING SYSTEMS FOR PRODUCTING CUCUMBER CROP UNDER HOT-HUMID SUMMER CONDITIONS', Journal of Soil Sciences and Agricultural Engineering, 1(10), pp. 1015-1036. doi: 10.21608/jssae.2010.75499
Abdellatif, S., Ibrahim, M., Ellithy, M. A COMPARTIVE STUDY ON TWO DIFFERENT EVAPORATIVE COOLING SYSTEMS FOR PRODUCTING CUCUMBER CROP UNDER HOT-HUMID SUMMER CONDITIONS. Journal of Soil Sciences and Agricultural Engineering, 2010; 1(10): 1015-1036. doi: 10.21608/jssae.2010.75499

A COMPARTIVE STUDY ON TWO DIFFERENT EVAPORATIVE COOLING SYSTEMS FOR PRODUCTING CUCUMBER CROP UNDER HOT-HUMID SUMMER CONDITIONS

Article 5, Volume 1, Issue 10, October 2010, Page 1015-1036  XML PDF (676.62 K)
Document Type: Original Article
DOI: 10.21608/jssae.2010.75499
View on SCiNiTO View on SCiNiTO
Authors
S. M. Abdellatif; M. M. M. Ibrahim; M. M. H. Ellithy
Agric. Eng. Dept., Fac. Agric., Mansoura Univ.
Abstract
The influence of greenhouse evaporative cooling systems (based on misting, and fan pads cooling systems) on the microclimatic conditions of greenhouse cucumber was studied and investigated in two fiberglass greenhouses combined with roof shading black net screen situated on the roof of the Agricultural Engineering Department, University of Mansoura. Measurements were executed during several days (122 days) in the hot summer of 2009; (G1) with a mist system operating 15 sec every 15 min., (G2) with a pad-fan system. In order to compare between the cooling systems, air temperatures and relative humidity inside and outside the greenhouses were measured and recorded. Experimental data revealed that the pad-fan cooling system was able to keep the air temperature within the greenhouse at rather low levels. The internal air temperature stayed 8.0°C below outside, even during hot afternoons (Tao > 35°C). Whereas, the evaporative cooling using mist system kept the greenhouse air temperature above the set point temperature by an average of 4.9°C. Therefore, the internal air temperature stayed 4.2°C below outside. Due to the short length of the greenhouse (8 m), small temperature gradients (2.9°C) were observed from wet pads to extracting fan. The cooling system using fan-pad system inside the greenhouse (G2) was on the average more efficient than the misting system inside the greenhouse (G1) by 22.5% due to the cooling operation period for the greenhouse (2) was longer than that for the greenhouse (1), accordingly, the water temperature of cooling system (2) was lower than that in misting system (G1). The total fresh yield of cucumber crop per square meter for greenhouse (G1) and greenhouse (G2) was 3.805 and 5.491 kg/m2, respectively. Therefore, the greenhouse (G2) produced 1.686 kg /m2 (44.31%) more than the greenhouse (G1).